MD32xxi cause iSCSI lost connection if any of the connected host rebooted

Yesterday, another Taiwan customer called, and explain to me the issue as below. At first, I thought this is the correct behavior of the MD. However, customer told me HP storage wouldn't have this issue. I ask him to send in the Support bundle, and found that the NVSRAM isn't the latest one. Convince him to upgrade to latest, or at least to A03. Finally, customer willing to update.

Just received his email few minutes ago, knowing that the issue resolved after upgrade to A02. :-)

Implementation:
3 (three) PowerEdge R710 connect to MD3200i. All hosts installed with VMWare VSphere 4.0.

Issue:
Whenever one of the host rebooted, it will not detect the MD3200i. Customer need to power cycle all R710 and MD3200i, in order to ensure all hosts can detect the MD again.

Solution:
Ensure MD3200i's RAID Controller firmware is the latest, or at least version A02.


Download link:
Dell MD32x0i iSCSI RAID Controller, v.CFW 07.75.10.60 and NVSRAM N26X0-775890-009, A02

  • Digg
  • Del.icio.us
  • StumbleUpon
  • Reddit
  • RSS

MD32xx/MD32xxi - Modular Disk Storage Manager (MDSM) may shows a 'NullPointerException' when launched in Chinese-based OS

Two days ago, a Taiwan customer called and complaint that he can't update the MD3200's NVSRAM to latest, due to Modular Disk Storage Manager (MDSM) is not showing proper Chinese words, and return an error: NullPointerException, when you wish to update the NVSRAM.

I use almost half a day to troubleshoot/gather relevant info from customer for analysis. Answer derive after 2-3 hours when I found one relevant article from our Knowledge-Base.

Cause:
This is the installer issue with the version A00 image with Spanish and Chinese OS language packages. This image doesn't impact any other language besides the two mentioned above.

Workaround:
1. For Windows:
- Ensure the Modular Disk Storage Manager application is closed
- Disable the Modular Disk Storage Manager Event Monitor service if it is started (through Windows services - Start->Run->services.msc)
- Navigate to the client directory under the MD Storage Manager installation directory (Default: C:\Program Files (x86)\Dell\MD Storage Software\MD      Storage Manager\client)
- Rename the SMclient.jar file to SMclient.orig.jar
- Copy  the provided SMclient-10.70.x6.06.jar file to SMclient.jar
- Re-enable the Modular Disk Storage Manager Event Monitor service (through Windows services)

2. For Linux
- Ensure the Modular Disk Storage Manager application is closed
- Navigate to the client directory under the MD Storage Manager installation directory (Default: /opt/dell/mdstoragesoftware/mdstoragemanager/client)
- Rename the SMclient.jar file to SMclient.orig.jar
- Copy  the provided SMclient-10.70.x6.06.jar file to SMclient.jar

In summary, if your OS language is either Chinese or Spanish, just ensure you download/install the MDSM from version A01 and above.

You may get the latest MDSM A04 from the link below:
http://supportapj.dell.com/support/downloads/download.aspx?c=my&cs=mybsd1&l=en&s=bsd&releaseid=R295070&SystemID=PWV_MD3200&servicetag=&os=WS8R2&osl=en&deviceid=22520&devlib=0&typecnt=0&vercnt=1&catid=-1&impid=-1&formatcnt=0&libid=52&typeid=-1&dateid=-1&formatid=-1&source=-1&fileid=441701

  • Digg
  • Del.icio.us
  • StumbleUpon
  • Reddit
  • RSS

Where to download Dell System Management Tools and Documentation (SMTD)?

After the previous post: How to install Microsoft Hyper-V in Dell 11th Generation server? , I received few enquiry on where to download Dell System Management Tools and Documentation (SMTD).


Please follow the steps below to prepare the SMTD v6.4:

1. Download both ISO from below:

Image 1: OM_6.4.0_SMTD_A00.iso.001 Image 2: OM_6.4.0_SMTD_A00.iso.002 
2.  Before you burn it out, you need to join both ISO become single ISO file.
        Windows:
copy /b OM_6.4.0_SMTD_A00.iso.001+OM_6.4.0_SMTD_A00.iso.002 OM_640_SMTD_A00.iso

             Linux
cat OM_6.4.0_SMTD_A00.iso.001 OM_6.4.0_SMTD_A00.iso.002 > OM_640_SMTD_A00.iso
3. After that, you may open the ISO file with your burning software such as Roxio or Nero, and burn it. 


After that, boot with this DVD to enter the Pre-Install configuration interface.

  • Digg
  • Del.icio.us
  • StumbleUpon
  • Reddit
  • RSS

How to install Microsoft Hyper-V in Dell 11th Generation server?

Yesterday, a visitor named Syedz inquiry how to install Hyper-V in R710. I thought I can reply him through email, but I didn't receive any email afterwards. In case you re-visit my site, here is the steps you required.

Steps

  1. Install your Windows Server 2008 with Dell System Management Tools & Documentation
  2. After that, boot with the Windows Server 2008 media.
  3. In the Setup Wizard, click the language you want to use during the installation.
  4. Next, select the language to be installed, along with the time and currency formats and the keyboard layour, and then click Next.
  5. Click Install Now, and then accept the license terms
  6. In the next screen, specify the location where you wan Hyper-V Server 2008 R2 to be installed, and then click Next.
  7. During the installation, server will restart several times. When the installation is complete, you will prompt for Administrator account setup. Click Ok.
  8. Give a strong password for the Administrator account, confirm, then press ENTER.
  9. When you see the message "Your password has been changed", click Ok.

That's all for the installation part. For Hyper-V configuration, allow me to took another 1 or 2 days to complete the post. :-)

Stay tuned for more updates.

Reference: www.microsoft.com

  • Digg
  • Del.icio.us
  • StumbleUpon
  • Reddit
  • RSS

EMC AX100/150's Power Supply's behavior

An India customer, report a fault for his EMC's AX100 with dual Storage Processor. He sent me the SPCollect, found that there is error for SPB, and Power Supply B. Due to this storage contained all critical information for his company, I have to arrange the onsite service with 2 standby parts: Storage Processor, and Power Supply.

Few hours later, onsite engineer feedback, and the call routed to me. After few checking with engineer, we confirmed that issue caused by human error, and there isn't any hardware fault from the AX100 when engineer reach site.

Cause:
Customer did accidentally disconnect the power cord to Power Supply B, and cause SPB down.

The behavior of the power supply as below:

  1. A failed power supply prevents operation of a single-processor AX-series
  2. On a dual-processor AX100, a failed power supply will power down the associated storage processor
  3. On a dual-processor AX150 or an AX150SC with two power supplies, a failed power supply will cause the system to run in degraded mode.

  • Digg
  • Del.icio.us
  • StumbleUpon
  • Reddit
  • RSS

Don't run ChkDsk to the degraded Virtual Disk

Recently I've done some review to few hard disk which configured with hardware RAID related cases, found that most of the hard disk replacement that lead to OS 'crash' is due to the server did gone through ChkDsk, either trigger by user or start automatically.
I do not know why until I found this article with the below statements:

"....Chkdsk is not RAID-aware. Its algorithms only work in the simplest cases. In general, it must be avoided. If chkdsk attempts to repair one or more member disks, the RAID data patterns will be destroyed, usually beyond recovery."
Frankly, I have no idea how true is the abovementioned statements, as I can't find any relevant info from Microsoft site. However, the experiences that I gone through with customer are real. In this moment, I think we should try to avoid running the Chkdsk when there is any hard disk failure (with hardware RAID configuration).

For more info, you may go to the link below:
http://www.quetek.com/RAID_mistakes.htm

  • Digg
  • Del.icio.us
  • StumbleUpon
  • Reddit
  • RSS

How to check Dell warranty?

If you feel sick or lazy to call up Dell Technical Support's toll-free number, wait in the queue just to check your system's warranty, you can just click on the link below, then key-in the Service Tag, and you will get the warranty status within a second:

http://support.dell.com/support/topics/global.aspx/support/my_systems_info/details?c=us&cs=555&l=en&s=biz&~ck=anavml
If your server, storage, switch or other Dell system is out-of-warranty, or warranty near to expiry date, a message will prompt as below:
Warranty contracts for your PowerEdge [model] have expired or will expire within 90 days.
Ensure your system is covered by contacting a Dell Extended Services Sales Agent at [toll-free for your region]
The real message as attached:
After that, you should see Service Contracts & Warranties, Original System Configuration, and Current System Configuration.


From the above attached picture, you can see the Start and End date, and how many days left for the valid warranty. If you wish to use the server/storage for another one or two years, do plan to get the quotation
from your sales account manager at least 21 days before the warranty expired.

Reference: http://supportapj.dell.com/support/index.aspx